Troy was very pleasant and professional. He conducted a comprehensive review of my AC system and made recommendations of future needs.
The service was very professional and thorough. The condenser and coils were cleaned and performance was tested. James Thornsberry is a true professional! Very happy with price.
Tony was on time and knew what he was doing. A/C back up and running perfectly in less than an hour. Would highly recommend Tony and Hot to Cold.
Had a last minute need on a weekend, was here to help in a couple hours, great service.
Yearly maintenance customer is a maintenance member.
Reconfigure the airflow: - Replace/redesign the supply plenum - Install manual dampers for adjuments - Relocate the supply vents and ductwork - Install proper supply air in the bathrooms - Install proper supply air in the office Perform a full air conditioning system maintenance Perform a Breathe Easy Duct Sanitation
Coil replacement completed Took out old coil Built new one with new txv valve Slid new coil in place and tie in copper and drain Flush drain line out Installed new filter drier Pressure tested and vacuumed copper lines Recharged unit and let ran for 20 minutes Adjusted charge Temperature difference was at 19-21 and home was cooling Unit was draining
Today we visited to determine why the a/c and heat aren’t working. Upon arrival the inside unit was turning on but the outside unit was not. The outside unit was receiving the voltage to energize the contactor but it was not pulling in because the low pressure sensor was tripped. The unit was entirely out of refrigerant. James added two lbs of R-410a to locate the leak. The leak is audible inside the evaporator coil. The system has a parts warranty until 2028. When the coil is replaced, since the unit has a parts warranty, we should also replace the TXV and primary drain pan.
Uv light that doesn’t need Maintenence for seven years kills all contaminants going through duct system and on hard surfaces
Couldn’t find a location send a technician that knows this place
Annual visit on two systems, carrier, and a train
This is the most basic equipment available for purchase today. It uses a single speed compressor and a single speed indoor fan. This unit is the least expensive to initially purchase and install.
Upon arrival compressor was lock wasn’t turning on Reason faulty capacitor 70/5 And also did one time maintenance self rinse evaporate coil wash condenser coil shop vacuum drain line. Unit is running
Today we visited to perform an evaluation per our Fall Promotion. The unit is cooling, but well past its expected life and the inside unit has biological growth and other performance issues. James will be putting together replacement information for Elizabeth’s consideration.
Today James followed up on the installation to perform a QA inspection prior to the final mechanical inspection. The unit looks great and is performing well. The installation is ready for inspection.
Brennan G The code for the thermostat is 395559
repair small refrigerant leak on the suction line braze joint could not find a leak bubble test, no bubbles